Product Center
The product is suitable for transmission and distribution lines with AC rated voltage of 3.6/6kV or less. The mechanical, physical and electrical properties of the cable meet the standard requirements of GB/T12706.1-2008 rated voltage 1kV (Um=1.2kV) and 3kV (Um=3.6kV) cable.
Use characteristics and main electrical performance indicators:
Cable laying temperature less than 0 DEG C; 2, the conductive wire core allowed working temperature are less than 70;
Short circuit (the longest duration of no more than 5S) the maximum temperature of the cable is 160 DEG C; bending radius of cable: 4, cable with single core 20 (d+D + 5%) multi core cable: 15 (d+D) + 5% (Note: D cable diameter were measured, mm, D as measured in diameter. The conductor of the MM)
Model, name, place of use, size, table 1, table 2
Model |
Name |
Place of use |
|
Copper core |
Aluminum core |
||
VV |
VLV |
PVC insulated PVC sheath power cable |
It can be laid in indoor, tunnel, pipe, cable trench, flammable and seriously corrosive place, and can not bear the effect of mechanical force |
VV22 |
VLV22 |
PVC insulated steel strip armoured PVC sheath power cable |
It can be laid on indoor, cable trenches, underground and seriously corroded places, and can not withstand tension. |
Table 2 single core cable
Nominal section mm2 |
Insulation thickness mm |
Steel strip thickness mm |
Sheath thickness mm |
The approximate outer diameter mm of the cable |
Approximate weight kg/km of cable |
The maximum DC resistance of conductor Omega km at 20 C |
Test voltage kV/min |
||
VV22 |
VLV22 |
||||||||
copper |
aluminum |
||||||||
1X10 |
1.0 |
0.2 |
1.8 |
12.1 |
348.0 |
265.0 |
1.83 |
3.08 |
3.5 |
1X16 |
1.0 |
0.2 |
1.8 |
13.4 |
432.0 |
331.0 |
1.15 |
1.91 |
3.5 |
1X25 |
1.2 |
0.2 |
1.8 |
13.6 |
574.0 |
415.0 |
0.727 |
0.120 |
3.5 |
1X35 |
1.2 |
0.2 |
1.8 |
14.6 |
699.0 |
478.0 |
0.524 |
0.868 |
3.5 |
1X50 |
1.4 |
0.2 |
1.8 |
16.4 |
870.0 |
569.0 |
0.387 |
0.641 |
3.5 |
1X70 |
1.4 |
0.2 |
1.8 |
17.5 |
1118.0 |
685.0 |
0.268 |
0.443 |
3.5 |
1X95 |
1.6 |
0.2 |
1.8 |
19.3 |
1444.0 |
844.0 |
0.193 |
0.320 |
3.5 |
1X120 |
1.6 |
0.2 |
1.9 |
25.0 |
1719.0 |
960.0 |
0.153 |
0.253 |
3.5 |
1X150 |
1.8 |
0.2 |
2.0 |
27.0 |
2046.0 |
1113.0 |
0.124 |
0.206 |
3.5 |
1X185 |
2.0 |
0.2 |
2.1 |
30.7 |
2671.0 |
1503.0 |
0.0991 |
0.164 |
3.5 |
1X240 |
2.2 |
0.2 |
2.2 |
33.3 |
3353.0 |
1818.0 |
0.0754 |
0.125 |
3.5 |
1X300 |
2.4 |
0.5 |
2.5 |
36.4 |
4072.0 |
2145.0 |
0.0601 |
0.100 |
3.5 |
Table 3 two core cable
Nominal section mm2 |
Insulation thickness mm |
Steel strip thickness mm |
Sheath thickness mm |
The approximate outer diameter mm of the cable |
Approximate weight kg/km of cable |
The maximum DC resistance of conductor Omega km at 20 C |
Test voltage kV/5min |
||
VV22 |
VLV22 |
||||||||
copper |
aluminum |
||||||||
2X4 |
1.0 |
0.2 |
1.8 |
13.1 |
210.0 |
160.0 |
4.61 |
7.41 |
3.5 |
2X6 |
1.0 |
0.2 |
1.8 |
14.1 |
264.0 |
192.0 |
3.08 |
4.61 |
3.5 |
2X10 |
1.0 |
0.2 |
1.8 |
16.7 |
393.0 |
242.0 |
1.83 |
3.08 |
3.5 |
2X16 |
1.0 |
0.2 |
1.8 |
18.8 |
541.0 |
334.0 |
1.15 |
1.91 |
3.5 |
2X25 |
1.2 |
0.2 |
1.8 |
22.2 |
794.0 |
469.0 |
0.727 |
1.20 |
3.5 |
2X35 |
1.2 |
0.2 |
1.8 |
24.5 |
1037.0 |
585.0 |
0.524 |
0.868 |
3.5 |
2X50 |
1.4 |
0.2 |
1.8 |
21.8 |
1227.0 |
620.0 |
0.387 |
0.641 |
3.5 |
2X70 |
1.4 |
0.2 |
1.9 |
24.7 |
1650.0 |
747.0 |
0.268 |
0.443 |
3.5 |
2X95 |
1.6 |
0.2 |
2.0 |
29.2 |
2213.0 |
988.0 |
0.193 |
0.320 |
3.5 |
2X120 |
1.6 |
0.2 |
2.1 |
31.3 |
2733.0 |
1186.0 |
0.153 |
0.253 |
3.5 |
2X150 |
1.8 |
0.2 |
2.2 |
34.7 |
3396.0 |
1462.0 |
0.124 |
0.206 |
3.5 |
2X185 |
2.0 |
0.2 |
2.2 |
39.2 |
4112.0 |
1726.0 |
0.0991 |
0.164 |
3.5 |
Table 4 three core cable
Nominal section mm2 |
Insulation thickness mm |
Steel strip thickness mm |
Sheath thickness mm |
The approximate outer diameter mm of the cable |
Approximate weight kg/km of cable |
The maximum DC resistance of conductor Omega km at 20 C |
Test voltage kV/min |
||
VV22 |
VLV22 |
||||||||
copper |
aluminum |
||||||||
3X4 |
1.0 |
0.2 |
1.8 |
17.3 |
489.0 |
414.0 |
4.61 |
7.41 |
3.5 |
3X6 |
1.0 |
0.2 |
1.8 |
18.4 |
577.0 |
472.0 |
3.08 |
4.61 |
3.5 |
3X10 |
1.0 |
0.2 |
1.8 |
21.2 |
800.0 |
559.0 |
1.83 |
3.08 |
3.5 |
3X16 |
1.0 |
0.2 |
1.8 |
23.5 |
1050.0 |
740.0 |
1.15 |
1.91 |
3.5 |
3X25 |
1.2 |
0.2 |
1.8 |
27.2 |
1465.0 |
976.0 |
0.727 |
1.20 |
3.5 |
3X35 |
1.2 |
0.2 |
1.9 |
30.7 |
2149.0 |
1372.0 |
0.524 |
0.868 |
3.5 |
3X50 |
1.4 |
0.2 |
2.0 |
31.3 |
2453.0 |
1486.0 |
0.387 |
0.641 |
3.5 |
3X70 |
1.4 |
0.2 |
2.1 |
33.6 |
3116.0 |
1763.0 |
0.268 |
0.443 |
3.5 |
3X95 |
1.6 |
0.5 |
2.2 |
38.3 |
4053.0 |
2216.0 |
0.193 |
0.320 |
3.5 |
3X120 |
1.6 |
0.5 |
2.3 |
41.9 |
4930.0 |
2609.0 |
0.153 |
0.253 |
3.5 |
3X150 |
1.8 |
0.5 |
2.5 |
47.1 |
6075.0 |
3174.0 |
0.124 |
0.206 |
3.5 |
3X185 |
2.0 |
0.5 |
2.6 |
50.9 |
7299.0 |
3721.0 |
0.0991 |
0.164 |
3.5 |
3X240 |
2.2 |
0.5 |
2.8 |
57.0 |
9213.0 |
4590.0 |
0.0754 |
0.125 |
3.5 |
3X300 |
2.4 |
0.5 |
3.0 |
31.1 |
11185.0 |
5438.0 |
0.0601 |
0.100 |
3.5 |